This product is suitable for fixed wiring (laving) of power devices with an AC rated voltage of450/750V and below.thas wide applications in low-voltage power lines, daily electrical, instrumentation, and telecommunications equipment.
Executive standard
GB/T5023-2008,JB/T8734-2016
Usage Features
GB/T5023-2008,JB/T8734-2016
▲ Long-term operating temperature of cable conductor: ordinary cable does not exceed 70°c,and temperature-resistantproducts do not exceed 90°c.
▲ The ambient temperature during cable laying should not be lower than 0°C;
▲ The allowable bending radius of the cable should not be less than 6 times the diameter of the cable.
Non-sheathed cable for fixed wiring(GB/T5023.3-2008)
60227IEC01(BV)450/750V Single core flexible conductor non-sheathed cable for general purpose
60227IEC02(RV)450/750V Single core flexible conductor non-sheathed cable for general purpose
602271EC05(BV)300/500V Single-core solid conductor non-sheathed cable with conductortemperature of 70'C forinternal wiring
60227IEC06(RV)300/500V Single-core flexible conductor non-sheathed cable with conductortemperature of 70'C for internal wiring
Flexible cables(GB/T5023.5-2008)
60227EC52(RVV)300/300V Light Pvc sheathed flexible wire
60227IEC53(RVV)300/500V General PVc sheathed flexible wire
The insulation of cross-linked polyethylene insulated power cables adopts cross-linked polyethylene, which useschemical methods to convert linear molecular polyethylene into cross-linked polyethylene with a three-dimensionalnetwork structure, thereby greatly improving the mechanical properties of polyethylene and maintaining excellentelectrical properties.
PVC insulated power cables have good electrical performance and chemical stability.simple structure andconvenient use, suitable for fixed installation on transmission and distribution lines with AC 50Hz and rated voltage olkV and below, Five core power cables are used to separate the neutral and neutral lines in low-voltage distributionsystem engineering to meet the development and safety performance needs of the distribution system, making thesystem operation more stable and ensuring the safety of workers.
This product is suitable for overhead power lines with a rated voltage of 0.6/1kV and below, and can be used as afixed laying or incoming line. This product is extruded with weather resistant high-density polyethylene and weatherresistant polyvinyl chloride insulation outside tightly pressed copper and aluminum conductors. The cable is safe ancreliable, while also possessing excellent mechanical and electrical properties. Advantages such as resistance to electricatraces, surface discharge, and atmospheric conditions. The cable laying gap is smal, saving line corridors, reducing linevoltage, reducing power supply accidents, and ensuring personal safety. it is suitable for mountainous areas, forest areasmining areas, cities, and other occasions, and is an all-weather cable product.
This product is suitable for overhead power lines with a rated voltage of 10kV and below, and can be used as a fixed layingor incoming line, This product is extruded with weather resistant insulation outside tightly pressed copper and aluminumconductors, ensuring safe and reliable cable performance, while also possessing excellent mechanical and electrical propertiesAdvantages such as resistance to electrical traces, surface discharge, and atmospheric conditions. The cable laying gap is smallsaving line corridors, reducing line voltage, reducing power supply accidents, and ensuring personal safety. lt is suitable formountainous areas, forest areas, mining areas, cities, and other occasions, and is an all-weather cable product.
This product is suitable for power transmission and distribution lines with rated voltage of 10kV and below and certaintensile resistance reguirements, Due to its abilitv to withstand a certain tensile streneth,the instalation spacing can be increasedand the laving and operating environment reguirements are more flexible and convenient.
Purpose: Used in control, monitoring, circuits, and protection circuits with rated voltage of 450/750V and below. TyPe:KVV,KVWP,KVWP2,KVVP22,KVW22,KWWP2-22,KWR,KVWRP,KVW32.etc. Specification:nominal cross-section: 0.75-10mm',number of cable cores: 2-6l cores.
Purpose: Used in control, monitoring circuits, and protection circuits with rated voltage of 450/750V and below. Model:KYJV, KYJVP. KYJVP2、 KYJVP22. KYJV22、 KYJVP2-22、 KYJVR、 KYJVRP, KYJV32. KYJY, KYJYP etc. Specification: nominal section:0.75-10mm 2,Number of cable cores: 2-61
Applicable to 1kv-3kV voltage levels, cable operating temperature of 90'c in dry locations;can be installed verticallyindoors and outdoors, as well as on brackets or along walls;widely used in civil buildings, commercial, industrial, largevenues,entertainment venues,and other applications.
This product is suitable for fixed wiring (laving) of power devices with an AC rated voltage of450/750V and below.thas wide applications in low-voltage power lines, daily electrical, instrumentation, and telecommunications equipment.
lt is used to ensure the uninterrupted operation of fire-fighting power and important equipment such as firepumps,fire elevators, local lighting, emergency evacuation instructions, security monitoring, smoke evacuation systems, andself-contained power supplies in case of fire.